Inquire Now

Please enable JavaScript in your browser to complete this form.

Liquicap FTI52 Capacitance Point Level Detection

Specifications

  • Measuring Principle:
    Capacitive Liquid
  • Process Temperature:
    -80°C to +200°C (-112°F to +392°F)
  • Process Pressure:
    Vacuum to 100 bar (Vacuum to 1450 psi)
  • Ambient Temperature:
    -50°C to +70°C (-58°F to +158°F)
    With separate housing: -50°C to +120°C (-58°F to +248°F)
  • Max Sensor Length:
    12 m (39 ft)
  • Main Wetted Parts:
    Insulation materials: FEP, PFA
    Stainless Steel: 316L

Applications

Field of Application:
The Liquicap FTI52 is specifically designed for point level detection in:-

-Highly viscous liquids that tend to form build-up.
-Detection of interfaces between different liquids.
-Foam detection in conductive liquids.
-It allows two-point control (e.g., pump control) using a single process connection.
-The probe features active build-up compensation, enhancing reliability across various applications. The components in contact with the process are constructed from corrosion-resistant and FDA-listed materials, ensuring a high safety standard.

Benefits

  • Cost Efficiency:
    Quick and easy commissioning with calibration accomplished at the press of a button.
  • Reliability:
    Active build-up compensation ensures consistent and safe measurements.
  • Wide Application Range:
    Supported by various international certificates and approvals.
  • Fast Reaction Time:
    Short response time for reliable operation.
  • Durable Construction:
    Use of corrosion-resistant and FDA-listed materials enhances longevity.
  • Enhanced Protection:
    Equipped with two-stage overvoltage protection.
  • No Recalibration Required:
    No need for recalibration after electronic replacements.
  • Design and Installation:
    Process Connections: Flanges, threads, and specialized hygienic process connections, including: G3/4 to G1 1/2 NPT 3/4 to NPT 1 1/2
    Flange connections: from DN25 and ASME standards.
    Hygienic Connections: Tri-Clamp ISO2852, dairy coupling, flush-mounted options available.
  • Communication and Power Supply
    Power Supply Options: 2-wire (19-253 VAC), 3-wire configurations.
  • Communication Protocols:
    PFM, Relay DPDT, DC-PNP, 8/16 mA.

Approvals and Certificates

  • Explosion Protection:
    ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI, EAC.
  • Safety Approvals:
    Overfill prevention WHG and SIL compliance.
  • Design Approvals:
    EN 10204-3.1, NACE MR0175.
  • Marine Approvals:
    GL, ABS, DNV.
  • Application Limits:
    Users should be aware of pressure and temperature derating and the need for consideration when dealing with non-conductive media.
    The Liquicap FTI52 is a versatile and reliable solution for point level detection in various liquid applications, providing safety, durability, and ease of use in challenging conditions.