Liquicap FMI52 Capacitive Measurement for Various Liquids

Specifications

  • Measuring Principle:
    Capacitive
  • Accuracy:
    Repeatability: ±0.1%
    Linearity Error for Conductive Liquids: <0.25%
  • Max Measurement Distance:
    0.42 m to 10.0 m (1.38 ft to 33 ft)
  • Process Temperature:
    -80°C to 200°C (-112°F to 392°F)
  • Process Pressure:
    Vacuum to 100 bar (Vacuum to 1450 psi)
  • Ambient Temperature:
    -50°C to +70°C (-58°F to +158°F)
  • Main Wetted Parts:
    Insulation materials: FEP, PFA
    Stainless steel: 316L
  • Field of Application:
    The Liquicap FMI52 is designed for continuous level monitoring in liquids, particularly suited for:-
    Small tanks
    Build-up forming media
    Extreme temperature conditions
    The device operates independently of the dielectric constant (dc) for liquids with a conductivity of 100μS/cm or higher, allowing for accurate measurement without the need for recalibration. It is ideal for inventory management solutions when used with the Fieldgate FXA320 for remote value interrogation.

Benefits

  • Safety Compliance:
    Can be used in safety systems requiring functional safety to SIL2 according to IEC 61508.
  • Versatile Applications:
    Supported by a wide range of international certificates and approvals.
  • Factory Preconfiguration:
    No calibration required for conductive media, reducing setup time and costs.
  • Durable and Safe Materials:
    Corrosion-resistant materials ensure long-lasting performance.
  • User-Friendly Configuration:
    Optional menu-guided local configuration with a plain text display.
  • Enhanced Protection:
    Two-stage overvoltage protection for increased reliability.
  • Design and Installation:
    Process Connections: Flanges and threads, including G3/4, G1, G1 1/2, NPT options, and hygienic connections like Tri-Clamp ISO02852.
    Inactive Length: Maximum inactive length of 2 m (7 ft) with a total sensor length of 6 m (20 ft).
  • Supply and Communication:
    Supply Voltage: 12-36 V DC
  • Communication Protocols:
    4…20 mA HART, PFM

Approvals and Certificates

  • Explosion Protection:
    ATEX, FM, CSA, IEC Ex, TIIS, INMETRO, NEPSI, EAC
  • Safety Approvals:
    SIL compliance
  • Hygienic Approvals:
    EHEDG
  • Application Limits:
    Restrictions: Not suitable for changing, non-conductive media with conductivity < 100 μS/cm.
    Users should also be aware of pressure and temperature derating.