Inquire Now

Please enable JavaScript in your browser to complete this form.

Proline Promag P 300 Flowmeter Improved Connectivity Options

Specifications

  • Max Measurement Error:
    Volume Flow (Standard): ±0.5% of reading ± 1 mm/s (0.04 in/s)
    Volume Flow (Option): ±0.2% of reading ± 2 mm/s (0.08 in/s), Flat Spec
  • Measuring Range:
    4 dm³/min to 9600 m³/h (1 gal/min to 44,000 gal/min)
  • Medium Temperature Range:
    Liner Material PFA: –20 to +150 °C (–4 to +302 °F)
    Liner Material PFA High-Temperature: –20 to +180 °C (–4 to +356 °F)
    Liner Material PTFE: –40 to +130 °C (–40 to +266 °F)
  • Max Process Pressure:
    PN 40, Class 300, 20K
  • Wetted Materials:
    Liner: PFA; PTFE
  • Electrodes:
    1.4435 (F316L)
    Alloy C22, 2.4602 (UNS N06022)
    Tantalum
    Platinum
    Titanium

Applications

The Promag P is specifically designed for chemical and process applications that involve corrosive liquids and high medium temperatures. With its compact transmitter (Promag P 300), it provides high flexibility regarding operation and system integration. Features include access from one side, a remote display, and enhanced connectivity options.

Heartbeat Technology ensures compliance and process safety at all times. The bidirectional measuring principle operates with minimal dependency on pressure, density, temperature, and viscosity, making it ideal for various industrial applications.

Device Properties

  • Nominal Diameter: Max DN 600 (24″)
  • Ex Approvals: All common Ex approvals
  • Liner Materials: Available in PTFE or PFA
  • Housing: Compact dual-compartment design with up to 3 I/Os
  • Display: Backlit display with touch control and WLAN access
  • Remote Display: Available
  • Measuring Principle: Electromagnetic

    Proline Promag P 300 electromagnetic flowmeter
    High-temperature flowmeter for process applications with a compact, easily accessible transmitter dedicated to chemical and process applications involving corrosive liquids and high medium temperatures.

Features

  • Sensor Features:
    Diverse applications with a wide variety of wetted materials
    Energy-saving flow measurement with no pressure loss due to cross-section constriction
    Maintenance-free operation with no moving parts
    Nominal Diameter: Max DN 600 (24″)
    All common Ex approvals
  • Transmitter Features:
    Full access to process and diagnostic information with numerous, freely combinable I/Os and fieldbuses
    Reduced complexity and variety with freely configurable I/O functionality
    Integrated verification through Heartbeat Technology
    Liner materials: PTFE or PFA
    Compact dual-compartment housing with up to 3 I/Os
    Backlit display with touch control and WLAN access
    Remote display available

Technical Details

  • Nominal Diameter Range:
    DN 15 to 600 (½ to 24″)
  • Wetted Materials:
    Liner: PFA; PTFE
  • Electrodes:
    1.4435 (F316L)
    Alloy C22, 2.4602 (UNS N06022)
    Tantalum
    Platinum
    Titanium
  • Measured Variables:
    Volume flow
    Conductivity
    Mass flow
  • Max Measurement Error:
    Volume Flow (Standard): ±0.5% of reading ± 1 mm/s (0.04 in/s)
    Volume Flow (Option): ±0.2% of reading ± 2 mm/s (0.08 in/s), Flat Spec
  • Measuring Range
    4 dm³/min to 9600 m³/h (1 gal/min to 44,000 gal/min)
  • Max Process Pressure
    PN 40, Class 300, 20K
  • Medium Temperature Range
    Liner Material PFA: –20 to +150 °C (–4 to +302 °F)
    Liner Material PFA High-Temperature: –20 to +180 °C (–4 to +356 °F)
    Liner Material PTFE: –40 to +130 °C (–40 to +266 °F)
  • Ambient Temperature Range
    Flange Material Carbon Steel: –10 to +60 °C (+14 to +140 °F)
    Flange Material Stainless Steel: –40 to +60 °C (–40 to +140 °F)
  • Sensor Housing Material:
    DN 15 to 300 (½ to 12″): AlSi10Mg, coated
    DN 350 to 600 (14 to 24″): Carbon steel with protective varnish
  • Transmitter Housing Material:
    AlSi10Mg, coated;
    1.4409 (CF3M) similar to 316L;
    Stainless steel for hygienic transmitter design
  • Degree of Protection:
    Standard: IP66/67, Type 4X enclosure
  • Display/Operation:
    4-line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools is possible
    Remote display available
    -Outputs
    3 Outputs:
    4-20 mA HART (active/passive)
    4-20 mA WirelessHART
    4-20 mA (active/passive)
    Pulse/frequency/switch output (active/passive)
    Double pulse output (active/passive)
    Relay output
    -Inputs
    Status Input
    4-20 mA Input
  • Digital Communication:
    HART
    PROFIBUS DP
    PROFIBUS PA
    FOUNDATION Fieldbus
    Modbus RS485
    PROFINET
    PROFINET over Ethernet-APL
    Ethernet/IP
    OPC-UA
  • Power Supply:
    DC 24 V
    AC 100 to 230 V
    AC 100 to 230 V / DC 24 V (non-hazardous area)

Approvals and Certificates

  • Hazardous Area Approvals:
    ATEX
    IECEx
    cCSAus
    INMETRO
    NEPSI
    EAC
    JPN
    UK Ex
    KC
  • Product Safety:
    CE
    C-tick
    EAC marking
  • Functional Safety:
    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511.
  • Metrological Approvals and Certificates:
    Calibration performed at accredited calibration facilities (according to ISO/IEC 17025)
    Heartbeat Technology complies with requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
  • Marine Approvals and Certificates:
    LR approval
    DNV approval
    ABS approval
    BV approval
  • Pressure Approvals and Certificates:
    PED
    CRN
    Material Certificates
    3.1 material
  • Hygienic Approvals and Certificates:
    ACS
    NSF 61
    WRAS