Proline Prosonic Flow W 400 ultrasonic clamp-on flowmeter

Proline Prosonic Flow W 400 ultrasonic clamp-on flowmeter

Product Details

9W4BA1-DE08/0

Prosonic Flow W 400 is the ultrasonic clamp-on flowmeter of choice for safe, cost-effective and maintenance-free measurement of conductive and non-conductive liquids. It measures flow noninvasively and bidirectionally, independent of pressure, density and conductivity, and without process interruption.FlowDC makes mounting as flexible as never before. The specified accuracy is maintained at an inlet run of only 2 x DN, even in the case of disturbed flow profiles.
Special coupling pads make this ultrasonic clamp-on system maintenance-free during the entire product life cycle.
Heartbeat Technology provides continuous process transparency with its diagnostic, verification and monitoring functions. This way, build-up can be detected before it affects operation.

Prosonic Flow W 400 is the ultrasonic clamp-on flowmeter of choice for safe, cost-effective and maintenance-free measurement of conductive and non-conductive liquids. It measures flow noninvasively and bidirectionally, independent of pressure, density and conductivity, and without process interruption.FlowDC makes mounting as flexible as never before. The specified accuracy is maintained at an inlet run of only 2 x DN, even in the case of disturbed flow profiles.
Special coupling pads make this ultrasonic clamp-on system maintenance-free during the entire product life cycle.
Heartbeat Technology provides continuous process transparency with its diagnostic, verification and monitoring functions. This way, build-up can be detected before it affects operation.

Product Configuration

9W4BA1-DE08/0

9W4BA1-AALHFPAAEFABABA2

Cable Entry:

3

Gland M20

Housing:

B

Stainless, hygienic

Electrical Connection:

A

Gland M20

Meas. Tube Mat., Wetted Parts Surface:

SA

Stainless steel, not polished

Process Connection:​

D2S

PN40, 1.4404/316/316L, flange EN1092-1-B​

Calibration Flow:

A

0.10% Mass

Device Model:

A2

2

Details:

A2

Select medium: Liquid

Curr. output 1: Mass flow

Current span: 4...20 mA NAMUR

4 mA value: 0 kg/h

20 mA value: 15000.000000 kg/h

Failsafe mode current output: Max.

Damping output 1: 1.000000 s

Operating mode: Pulse

Assign pulse output: Mass flow

Pulse value (per pulse): 10.000000 kg

Failsafe mode pulse output: No pulses

Format display: 1 value, max. size

Value 1 display: Mass flow

Value 2 display: None

Value 3 display: None

Value 4 display: None

Display damping: 0 s

Totalizer 1: null

Unit: kg

Operating mode totalizer: Net flow total

Failure mode: Stop

Totalizer 2: null

Additional information

Approval; Transmitter + Sensor:

AA : Non-hazardous area

Power Supply:

L : AC 100…240V, AC/DC 24V

Output; Input:

H : 4-20mA HART, pulse/freq., switch output

Display; Operation:

F : 4-line illum.; touch control

Transmitter Housing:

P : Remote, alu, coated

Electrical Connection:

A : Gland M20

Sensor Version:

AE : C-500 (5 MHz)

Process Temperature:

F : 0…130oC, 32…266oF

Cable:

AB : 10m/30ft, -40…80oC, -40…176oF

Installation Set:

AB : DN32-DN65, 1 1/4-2 1/2"

Device Model:

A2 : 2

Product Details​
Prosonic Flow W 400 is the ultrasonic clamp-on flowmeter of choice for safe, cost-effective and maintenance-free measurement of conductive and non-conductive liquids. It measures flow noninvasively and bidirectionally, independent of pressure, density and conductivity, and without process interruption.FlowDC makes mounting as flexible as never before. The specified accuracy is maintained at an inlet run of only 2 x DN, even in the case of disturbed flow profiles.
Special coupling pads make this ultrasonic clamp-on system maintenance-free during the entire product life cycle.
Heartbeat Technology provides continuous process transparency with its diagnostic, verification and monitoring functions. This way, build-up can be detected before it affects operation.

Product Configuration

9W4BA1-DE08/0

9W4BA1-AALHFPAAEFABABA2

Additional information

Approval; Transmitter + Sensor:

AA : Non-hazardous area

Power Supply:

L : AC 100…240V, AC/DC 24V

Output; Input:

H : 4-20mA HART, pulse/freq., switch output

Display; Operation:

F : 4-line illum.; touch control

Transmitter Housing:

P : Remote, alu, coated

Electrical Connection:

A : Gland M20

Sensor Version:

AE : C-500 (5 MHz)

Process Temperature:

F : 0…130oC, 32…266oF

Cable:

AB : 10m/30ft, -40…80oC, -40…176oF

Installation Set:

AB : DN32-DN65, 1 1/4-2 1/2"

Device Model:

A2 : 2

Interested in this product? Request a quote today!